Before Picture
This is an example of the work we do. This is a Tuttnauer autoclave where you'll see before and after pictures of our service. Pictures speak for themselves.
Before Picture
Old worn out door gaskets can cause steam to leak and cause chamber to lose pressure. If you notice cracking, warping, or steam is seeping out from the door it is time to change the door gasket.
After Picture
New door gasket is installed to insure a tight seal once door is closed to keep steam escaping prematurely from the chamber.
Before Picture
Here is a chamber with build up of black residue that could result in premature failure of components or damage to delicate surgical instruments. Over time this residue or foreign matter can build up enough to clog the tubes which transport water from the reservoir which is needed to produce steam to sterilize surgical tools.
After Picture
We use a strong cleaning base solution to remove and scrub out the black residue to insure you have clean heating surfaces. The heat radiation processes need clean, uniform surfaces to insure a fully effective drying cycle.
Before Picture
A closer view of the dirty chamber.
After Picture
A closer view of a clean chamber.
Before Picture
In the back of the chamber you have an exhaust port hole above that allows steam to escape during the exhaust cycle and a water port hole below that allows enough water to fill in chamber as needed for sterilization cycle. If you notice, something here is missing. There's nothing to prevent these port holes and tubing behind that from getting clogged up with foreign matter that could potentially damage the autoclave.
After Picture
We install what is called fill/vent mesh chamber filters that will help prevent premature build up of foreign matter in the tubes that can lead to disfunction of your autoclave.
Before Picture
This is a safety door switch. This switch prevents the autoclave heating element from heating or burning out while door is open in the sterilization position. Safety switch is exposed to steam that can damage the internal components of the switch and over time cause switch to stick in on or off position only. If it sticks in the on position, the heating element will remain on while the door is open during sterilization cycle position. If it sticks in off position, the autoclave will not power up. Should this happen, the door switch will have to be replaced. This is a common problem on Tuttnauer autoclaves without a rubber boot on safety door switch.
After Picture
We install rubber boot for door switch on Tuttnauer autoclaves as necessary to prevent damage to the internal components of the safety door switch.
Before Picture
This is an internal view of the reservior which holds distilled water. Water has been drained in order to remove the slime and sludge during the cleaning process.
After Picture
We help clean out any debris in reservior to prevent damage to the internal components and extend life of your autoclave
Before Picture
Over time your reservior can look like this without preventative maintenance.
After Picture
Keeping reservior clean can insure longer life of your autoclave.
Before Picture
Over so many repetitious sterilization cycles, trays eventually get gummed up with baked on residue of foreign matter that oxidizes to these surfaces.
After Picture
We help remove the baked-on residue and oxidation matter on tray holder and trays to insure a clean uniform surface for more efficient drying of packs or surgical tools.
Before Picture
We further inspect to make sure autoclave is heating properly and puts out recommended temperature according to manufacture specifications. Thermometer is used to confirm temperature and insures temperature gauge is working properly.
After Picture
We take the extra time needed to make sure the internal thermostat is calibrated properly to insure autoclave is putting out the desired heat necessary for sterilization and not overheating. Timer is also tested to insure optimal performance.
Back | Forth
Autoclave Preventative Maintenance Details
Valley Microscope strongly recommends a professional cleaning overhaul on autoclave (sterilizer) equipment if the chamber contains build-up of rust, greenish or black residue that could result in premature failure of components or damage to delicate surgical instruments, and reservoir is dirty or built up with foreign matter that can clog up your tubes therefore reducing the life of your sterilizer. Processing sterile goods under these conditions can be at the least distasteful, but more importantly, can be less efficient than processing in a clean chamber. The heat radiation processes need clean, uniform surfaces to insure a fully effective drying cycle. Our preventative maintenance cleaning service will help reduce the frequency of equipment malfunction and the risk of accidental contamination of sterile items. Preventative maintenance includes cleaning chamber, reservoir, tray holder, and trays with a solution that is super effective and safe in dissolving the crud & removing the nasty residue from the stainless steel components. Furthermore, we clean reservoir and the plumbing tubes channeling into it by using another solution that will flush out the build up of gunk or other foreign matter. This cleaning solution is ran through a few sterilization cycles through the plumbing system to insure harmful deposits in the valves and tubes are removed, then we drain the solution and flush out the tubes with distilled water. We also test the temperature and timer to make sure they're operating at peak performance. We then strive to provide this service on-site in your lab and it generally takes about 3 hours to service an autoclave(sterilizer) if no known problems are discovered during our testing procedures and no repairs are needed.

Before we can perform a cleaning on a sterilizer we need to know the make, model #, and serial number of your autoclave, and if you're having any other issues with it so that we can obtain correct parts necessary to restore your autoclave in good working order. As the autoclave is being cleaned we inspect valves, filters, gaskets, and electronic components to insure reliable service. This scheduled cleaning and inspection will prolong the dependable life of your autoclave. Get a free estimate below based on your type of autoclave/sterilizer!
    Benefits of Autoclave (Sterilizer) Cleaning:
  • Improves sterilizer operating efficiency
  • Uniform surface provides more efficient drying
  • Removes the baked-on residue and oxidation
  • Restores original factory finish
  • Future maintenance is easier and possible
  • Reduces cost by preventing unnecessary costly repairs
  • Autoclave/Sterilizer Preventative Maintenance & Cleaning Service fee starts at $295.00 plus the door gasket or PM Kit.
    Bigger size units such as Tuttnauer 3870 and Pelton & Crane Magnaclave models, fee starts at $395.00.
    Free travel expense up to 75 miles from Winchester, VA. Additional fee may apply if you're outside this territory.

    Select your autoclave/sterilizer make & model door gasket or (Preventative Maintenance)PM Kit (Sales Tax not included):



    Please fill out this short form below.
    By providing us with this valuable information will enable us to keep popular make & model
    autoclave/sterilzer parts in stock and be able to setup appointments for service more quickly.


    YOUR NAME, ADDRESS AND PHONE NUMBER WILL REMAIN STRICTLY CONFIDENTIAL.
    YOUR INFORMATION WILL NEVER BE RENTED OR SOLD TO THIRD PARTY AFFILIATIONS.

    *Autoclave/Sterilizer
    YESNO Check box if you're human!

    Autoclave Repair Service

    Generally we perform diagnostic test and inspect components first, identify the parts that need replacement, and provide an estimate of repair and obtain authorization first before initiating any repairs.

    If you answer YES to any of the following questions below, we have a solution for the problem.
    Don't delay, contact us now so we can help take care of any one of these matters for you.

  • Did someone tell you that your chamber (tank) has a hole in it & is not worth repairing?
  • After pressure build does it begin to drop?
  • Are the trays totally black & burned?
  • Does water leak from the door unless you press down on the door handle?
  • Does the yellow light (heat) stay off frequently?
  • Are the bags being burned?
  • Does the temperature gauge pass 270 degrees?
  • Are you replacing heaters more than once a year?
  • Does it take a long time to fill the chamber with water?
  • Do you hear a loud noise when the safety valve opens?
  • Does it take longer than 15 minutes to build pressure?
  • Do you find the sterilizer on when you arrive in the morning?

We want to buy your unwanted autoclave, any condition! We are currently interested in purchasing Tuttnauer 2340M & 2540M models and Midmark Ritter M11 autoclaves.

Autoclave brands & models we repair


  • MIDMARK® - RITTER 7, M11, M11D, M7, M9, M9D

  • PELTON & CRANE Delta 10" (AF), Delta 8" (AE), Delta Q10, Delta Q8, Delta XL10, Delta XL8, FL, FL2, GN, HP, HP2, Magnaclave, OCM, OCR, OCR+, Sentry, Validator 10, Validator 8, Validator Plus 10, Validator Plus 8

  • TUTTNAUER® 1730E, 1730EK, 1730M, 1730MK, 2340E, 2340EA, 2340EK, 2340EKA, 2340M, 2340MK, 2540E, 2540EA, 2540EHS, 2540EK, 2540EKA, 2540M, 2540MK, 3850E, 3850EA, 3850EHS, 3850M, 3850MK, 3870E, 3870EA, 3870EHS, 3870M, EZ10, EZ10k, EZ9, Valueklave (1730 MKV)
  •  

    Previously wrist breitling replica uk were simply considered as mere gadgets that were used to see time but now they have evolved to rolex replica accessories that help to create impressions on their friends, colleagues and family members. These designer replica watches timepieces also satisfy those people who demand and expect more from their life. Since cheap replica watches follow the latest models of the original brand, they are stylish, accurate, fully functional, durable and comfortable and all these features make them popular among all age groups. All these replica timepieces score quite high when it comes to selecting quality rolex replica that are available at moderate costs and sold by reputed online stores.

    Copyright ©2005-2016 Valley Microscope, LLC - All Rights Reserved.

    The contents of this site, text, graphics and computer code inclusive, are protected by copyright laws worldwide and may not be copied, reprinted, published or distributed by any means without explicit permission of the copyright holder.
    All other brands and product names are trademarked or registed trademarks of their respective companies. Prices and configurations included on this site are subject to change without notice or obligation.